| Make sure each line’s circuit type and loop length setting match the requirements of the connected service. |
| Option | Description |
|---|---|
| 00 | Uninstalled. |
| 01 | [Default] Loop Start. |
| 02 | Ground Start1 |
| 03 | DID Wink Start1 |
| 04 | DID Immediate Start1 |
| 05 | E&M Wink Start1 |
| 06 | E&M Immediate Start1 |
| 1Requires T1/PRI PCB1 |
| Indicate whether the line is DTMF or Dial Pulse. |
| Option | Description |
|---|---|
| No (0) | Dial Pulse. |
| Yes (1) | [Default] DTMF. |
| For analog lines only, use this option to compensate for the telco circuit loop length. |
| For normal installations, enter 0 (medium). |
| If the system is very close to the central office or behind a PBX, enter 1 (short). |
| If the loop length is abnormally long, enter 2 (long). |
| Option | Description |
|---|---|
| 0 | Medium. |
| 1 | Short. |
| 2 | [Default] Long. |
| Use this program to set the line access options. |
| Option | Description |
|---|---|
| 0 | No access. |
| 1 | Incoming access only. |
| 2 | Outgoing access only. |
| 3 | [Default] Full access. |
| Use this program to set the line ringing options. |
| Option | Description |
|---|---|
| 0 | Lamp only (no ringing) day and night. [Default] for DSX-80/160 extensions 316-427. |
| 1 | Day and night ringing. [Default] for DSX-40 (all) and DSX-80/160 extensions 300-315. |
| 2 | Night ringing only. |
| 3 | Delay ringing day and night. |
| Use this program to set the Delay Ring interval. A line set for Delayed Ringing will ring the extension after this interval. |
| Option | Description |
|---|---|
| 1-9999 | Seconds. [Default] = 10 seconds. |
| Enable this option to allow single line telephones to ring with a single ring for outside calls. |
| Disable this option to have line ringing at analog single line extensions follows the ringing pattern of the line. |
| Option | Description |
|---|---|
| No (0) | [Default] Disabled. |
| Yes (1) | Enabled. |
| Assign Class of Service to extensions. |
| Option | Description |
|---|---|
|
|
|